Skip to content Skip to navigation menu

Select Delivery Method

Please enter your delivery address to check availability.
Select delivery address
Please enter valid address
Add A Delivery Address* Please enter valid address
Can't find address?Try Address Form
e.g.
  1. Blackwoods - Level 4
  2. Level 4
  3. Unit 7
  4. Lot 684
  5. Shop 11
Address Line 1 * Please enter valid address
e.g.
  1. 39-43 High Street
  2. 26 Talavera Road
Address Line 2 Please enter valid address
Suburb * Please enter a valid suburb
Postcode
State
Switch to search address
Loading...
Please select your click and collect pick up Branch to check availability.
Loading...
click to open Expanded view
Schneider Electric Schneider Electric (View All Products)

Schneider Electric Acti 9 NG125 18639 Miniature Circuit-Breaker Acti9 NG125N 3P 63 A C Curve 25 Ka (IEC 60947-2)

  • Schneider Electric
  • BW#: 02305748
  • Mfr#: 18639
  • UNSPSC#: 39121603

Features
 • Acti9 iPRD Type 2 and 3 modular Surge Protection Devices protect the electrical equipments against the indirect lightning strikes
 • The use of Surge Protection Devices is recommended in the case of non-critical power installations
 • They are tested and rated according to the standardised current wave of 8/20 µs
 • With exclusive features, Acti9 iPRD DIN rail Surge Protection Devices are geared to protect your equipments from indirect lightning strikes and improve the continuity of service
 • The maximum discharge current covers from 8 to 65 kA
 • The maximum continuous operating voltage Uc is 350 VAC or 460 VAC
 • Withdrawable cartridges of Acti9 iPRD Surge arresters allow quick replacement of damaged devices
 • It is possible to use multipolar or unipolar products for serial assembly
 • The Acti9 iPRD surge arresters R version have dry contacts for transfering remotely the end-of-life information
 • The Acti9 iPRD8 Type 3 is placed in cascade near the loads to be protected
 • They should be installed in the secondary panel board, as soon as the distance from the incoming surge arrester is more than 10 meters, to ensure secondary protection
 • In a building with a height greater than 10 meters, with several dwellings, if a Type 1 surge arrester is installed in the main electrical switchboard, a Type 2 surge arrester must also be installed at the head of each divisional switchboards in order to distribute the constraints
 • In every new house without a lightning rod (primary protection) it is now mandatory to install in the electrical switchboard a Type 2 Surge Protection Device

Applications
 • Acti9 iPRD Type 2 Surge Protection Devices protect the electrical installations in all industrial and tertiary buildings against induced or conducted surges caused by indirect lightning strikes
 • These Type 2 Surge Protection Devices can be used also for the protection of residential installations
 • They are suitable for any earthing system TT, TN-S, TN-C and IT

Specifications

 • Certified for short-circuit current withstand, Isc up to 50 kA (IEC 61643-11: 2011)

Minimum sell quantity:

Order Quantity Multiple: